Improvements of a Certain Pontoon Bridge Cab¢s Frosting and Heating System
Received:March 03, 2019  Revised:April 07, 2019
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2019.09.019
KeyWord:pontoon-bridge equipment  cab  heating  frosting
              
AuthorInstitution
TIAN Jing Unit 32184, PLA, Beijing , China
ZHU Han-qing Unit 32184, PLA, Beijing , China
PEI Chao-yi Unit 32184, PLA, Beijing , China
YUAN Jing-jun Unit 32184, PLA, Beijing , China
HUANG Han-qing Unit 32184, PLA, Beijing , China
Hits:
Download times:
Abstract:
      Objective To solve the frosting and heating problems of certain pontoon bridge in cold region environment adaptability test. Methods Problems of the frosting and heating was analyzed with FTA, the correlative event was inspected. Improvement measures were proposed. The effect experiment was carried out in a comprehensive environmental laboratory. Results In the -40 ℃ environment, the cab¢s temperature was heated to 20 ℃ in 15 minutes, and. The interior surface of windshield had no frosting, and the exterior surface¢s defrosting area reached over 95%. Conclusions In condition of requirements for normal use and performance, the insufficient problems of cab¢s frosting and heating can be solved by adding fuel-air system and changing electrically heated vehicles-windshield.